EndedChatGPTLast seen Aug 23, 2026
best temperature sensors industrial applications high accuracy
Sponsored

MSE SuppliesSponsored
Witeg Drying Oven SWOV Vacuum Oven SmartLAb 19/30/70 Liter, 200°C, 10-750 MMHg
Witeg Drying Oven SWOV Vacuum Oven SmartLAb 19/30/70 Liter, 200°C, 10-750 MMHg Buy Witeg products from MSE Supplies at the best value. Ideal for Drying, baking, conditioning, curing, out-glassing solids and liquids, vacuum embedding, moisture testing, plating and aging test Features Very easy and convenient for vacuuming and venting, easy to read vacuum gauge High quality door sealing: high temperature grade silicone molded gasket Superior uniformity and stability Safety window: tempered safety glass 12T & polycarbonate 5T Compact new body design Stainless steel interior, powder-coated steel body and glass wool insulation 2x aluminium shelves included CE & UL/CUL certified and unique serial number for tracing Safety mechanism Push alarm service to your smartphone Overheat and over-current protection Sensor error detection and leakage breaker Controller Smart-Lab™ controller with 4? full touch screen TFT LCD: WiRe™ app service, remote control system Variable program settings Self-diagnostic function Automatic data recording Data transfer to PC by USB memory Internet connectivity with WiFi Recommended vacuum pump for 18.6l- and 30l-oven: Rocker 810Recommended vacuum pump for 70l-oven: Rocker 800/Rocker 811 Drying oven SWOV, 2 aluminium shelves, power cable, instruction manual Features SMART-LabTM Controller Full touch screen TFT LCD: WiRe™ app service, remote control system Variable program settings Self-diagnosis function Automatic data recording and password protection data transfer to PC by USB memory digital calibration (offset function) Min-/max-temperature memory & program function Push-alarm service to smartphone or tablet PC Temperature uniformity successfully tested by ASTM standards: All incubators and ovens are thoroughly tested, using 12 temperature sensors and the latest instruments to obtain validation, which corresponds to international standards. Green product: All incubators and ovens achieve minimum power consumption by using heating elements consuming minimum power adjusted for the capacity and temperature of the chamber. Technical data Version with Smart-LabTM controller, with vacuum inlet valve size outer Ø10 mm Length (inner) 290 mm Width (Outer) 480 mm Height (outer) 552 mm Heating time 60 min. to 100°C, 90 min. to 150°C Weight 48 kg Heating power 2 x 170 W, 2 x 130 W Power consumption 600 W Temperature control resolution Display 1.0°C, control 1.0°C Temperature fluctuation ±0.5°C at 100°C & 150°C Packing size 585 x 580 x 795 mm Width (inner) 265 mm Height (inner) 265 mm Length (outer) 475 mm Ideal for Drying, baking, conditioning, curing, out-glassing solids and liquids, vacuum embedding, moisture testing, plating and aging test Shelves 2 aluminium shelves included, height between shelves 87 mm Weight with packaging 59 kg Capacity 18.6 l Temperature variation ±2.0°C at 100°C, ±3.0°C at 150°C Temperature range Room temperature +5°C - 200°C Vacuum range 10 - 750 mmHg, 0.63 mbar, 0.39 mbar/h Controller Temperature sensor PT100 Comparison SKU Model Version Width (inner) Length (inner) Height (inner) Width (Outer) Length (outer) Height (outer) Ideal for DH.SWOV03020 SWOV-20 230 V with Smart-LabTM controller, with vacuum inlet valve size outer Ø10 mm 265 mm 290 mm 265 mm 480 mm 475 mm 552 mm Drying, baking, conditioning, curing, out-glassing solids and liquids, vacuum embedding, moisture testing, plating and aging test DH.SWOV03030 SWOV-30 230 V with Smart-LabTM controller, with vacuum inlet valve size outer Ø10 mm 300 mm 330 mm 300 mm 515 mm 515 mm 587 mm Drying, baking, conditioning, curing, out-glassing solids and liquids, vacuum embedding, moisture testing, plating and aging test DH.SWOV03070 SWOV-70 230 V with Smart-LabTM controller, with vacuum inlet valve size outer Ø10 mm 400 mm 435 mm 400 mm 618 mm 620 mm 687 mm Drying, baking, conditioning, curing, out-glassing solids and liquids, vacuum embedding, moisture testing, plating and aging test SKU Capacity Power consumption Temperature variation Temperature control resolution Temperature range Temperature fluctuation Vacuum range Packing size Controller DH.SWOV03020 18.6 l 600 W ±2.0°C at 100°C, ±3.0°C at 150°C Display 1.0°C, control 1.0°C Room temperature +5°C - 200°C ±0.5°C at 100°C & 150°C 10 - 750 mmHg, 0.63 mbar, 0.39 mbar/h 585 x 580 x 795 mm Temperature sensor PT100 DH.SWOV03030 30 l 600 W ±2.0°C at 100°C, ±3.0°C at 150°C Display 1.0°C, control 1.0°C Room temperature +5°C - 200°C ±0.5°C at 100°C & 150°C 10 - 750 mmHg, 0.63 mbar, 0.39 mbar/h 620 x 620 x 830 mm Temperature sensor PT100 DH.SWOV03070 70 l 1600 W ±2.5°C at 100°C, ±3.5°C at 150°C Display 1.0°C, control 1.0°C Room temperature +5°C - 200°C ±0.5°C at 100°C & 150°C 10 - 750 mmHg, 0.63 mbar, 0.39 mbar/h 725 x 720 x 930 mm Temperature sensor PT100 SKU Heating time Shelves Weight Weight with packaging Heating power DH.SWOV03020 60 min. to 100°C, 90 min. to 150°C 2 aluminium shelves included, height
Across all of MSE Supplies's ChatGPT ads, most appearances first. Prompts aren't recorded per ad yet.

MSE SuppliesSponsored
MSE Supplies Optical Profilometer Analytical Service
Overview An Optical Profilometer is an analytical tool used to measure and analyze the surface characteristics of materials with high precision. It employs non-contact optical techniques, typically using light interference or confocal microscopy, to generate detailed 3D surface images. This method allows for the accurate measurement of surface roughness, texture, and profile without damaging the sample. Optical profilometers are valuable in various fields, including materials science, semiconductor manufacturing, and precision engineering, providing crucial insights into surface quality and structural details essential for product development and quality control. Our Optical Profilometer can measure surface morphology, roughness, and height. Sample Requirement Samples should be flat, with a surface roughness of less than 300 μm. Sample size should not exceed 50 x 50 mm. Avoid testing powders; consideration will only be given for observing the surface morphology of piled powders in special cases. The powder should be fine, with an average particle diameter not exceeding 30 μm. * The price on our website is for reference only. * Note: Data analysis service is not included in the list prices. Highlights: High Quality Data, Competitive Pricing, Technical Support by Scientists. Analytical Service Minimum order requirement: $250 per order. A $200 handling fee will be applied if order is below $250. Please contact [email protected] for additional information and instructions on our Analytical Services program. Confirmation of the sample(s) requirements, SDS sheets and additional information is needed prior to processing the Analytical Service order. ***Please do not ship any samples without authorization from MSE Supplies*** | Optical Profilometer Analytical Service

MSE SuppliesSponsored
MSE PRO IN625 Inconel 625 Nickel Based Metal Powder for Additive Manufacturing (3D Printing) | 45~105 um
Product details: Inconel 625 additive manufacturing metal powder can be used to make Inconel 625 alloy by additive manufacturing or 3D printing. Inconel 625 is a nickel-based super alloy that possesses high strength properties and resistance to elevated temperatures. It also demonstrates impressive protection against corrosion and oxidation. Its ability to withstand high stress and a vast range of temperatures, both in and out of water, as well as being able to resist corrosion while being exposed to highly acidic environments makes Inconel 625 a fitting choice for nuclear and marine applications. SKU#: MP0170 (particle size: 0~25μm) MP0171 (particle size: 0~45μm) MP0172 (particle size: 15~45μm) MP0173 (particle size: 45~105μm) MP0174 (particle size: 75~180μm) Chemical Composition: Chemical Composition (wt%) of Inconel 625 Item Fe C Mn Si Ni Cr Mo V W Al In625 ≤5.0 ≤0.1 ≤0.5 ≤0.5 Bal. 20.0~23.0 8.0~10.0 - - ≤0.4 Mg Cu Ti Nb Zr P S Co - ≤0.07 ≤0.4 3.15~4.15 - ≤0.015 ≤0.015 ≤1.0 Oxygen≤400 ppm; Nitrogen≤300 ppm Particle Size (This size is D50): 0~25μm, 0~45μm, 15-45μm, 45~105μm, 75-180μm. (A variety of particle size metal powder can be customized upon request) Applications: Inconel 625 additive manufacturing metal powder can be used in laser/electron beam additive manufacturing (SLM/EBM), powder metallurgy (PM), spraying and other processes. Nickel-based metal powder is widely used in industrial and aviation turbines, petrochemical industry, nuclear reactors, laser cladding and other fields. Applicable Equipment: Powder can be used in various types of metal 3D printers, including Renishaw from the UK, EOS (EOSINT M series) from Germany, Concept Laser, 3D systems from the United States and many other laser melting equipment. Minimum Order Quantity: 1kg Note: The metal powder price varies due to the particle size range and the raw material price. | MSE PRO IN625 Inconel 625 Nickel Based Metal Powder for Additive Manufacturing (3D Printing) | 45~105 um, 45-105 um

MSE SuppliesSponsored
MSE Supplies Rheometer Analytical Service
Introduction to Rotational Rheometer Measurement Systems (Rotors): Coaxial Cylinder System (CC): Typically used for low-viscosity liquids but suitable for a wide range of fluids from low-viscosity to viscoelastic materials (e.g., from water-like samples to semi-solid creams). Easy sample loading with volume markers in the measurement cup. The large external surface area of the cup enables effective temperature control and prevents low surface tension fluids from spilling. Solvent evaporation can be minimized using special shields or evaporation covers. Frosted or grooved surfaces prevent wall slippage, and disposable cups and cylinders are available for testing hard-to-clean samples. Double Gap Measurement System (DG): According to ISO/WD 3219-2, this system uses a special rotor to maximize the contact surface area between the sample and the measurement system. Ideal for low-viscosity liquids like water, with high torque resolution. Advantages include a large surface area, excellent thermal stability, and minimal turbulence even at high shear rates. Cone-and-Plate Measurement System: Suitable for a wide range of fluids with minimal sample volume requirements. For dispersions, the maximum particle size must be limited (˂10 µm). Provides consistent shear conditions and is easy to clean. Rapid temperature adjustment ensures quick thermal equilibrium. Accessories like protective shields or solvent evaporation covers can be used to minimize solvent loss. Parallel Plate Measurement System: Recommended for testing pastes, gels, soft solids, or high-viscosity polymer melts, requiring relatively small sample volumes. Adjustable gap settings allow flexible measurement conditions. Suitable for high-viscosity samples (including uncrosslinked silicone), dispersions with large particle sizes, gels (with 3D superstructures), and soft solids (e.g., cheese, elastomers). Offers quick and easy cleaning. Testing Modes: Dynamic Viscosity Testing (Rotational Mode):Measures the fluid's viscosity under rotational motion. Modulus Testing (Oscillatory Mode):Determines the complex modulus (G*), storage modulus (elastic modulus, G’), loss modulus (viscous modulus, G’’), tanδ, and complex viscosity. Thixotropic Loop Test:Evaluates the thixotropic properties of materials, indicating their structural recovery capability. Structural Recovery Test:Assesses the material's ability to rebuild its structure after being disrupted. Creep Recovery Test:Measures deformation under stress and the recovery behavior once the stress is removed. Yield Stress Test:Determines the yield stress of the material. Sample Requirement Liquid Samples: Prepare 5–30 mL of the sample. For low-viscosity liquids, prepare a larger volume; for high-viscosity liquids, a smaller volume is sufficient. Solid Samples: Determine the appropriate solvent for dilution and specify the concentration. Solid Samples (Disk Form): Solid samples can be prepared as disks with specific dimensions, typically 20 mm or 35 mm in diameter and 1–3 mm in thickness, for testing in oscillatory mode. Multiple Tests: If testing the same sample in different modes, it is recommended to prepare multiple portions of the sample. As a general rule, liquid samples are standard. For semi-solid or solid samples, please notify in advance. The samples should have a certain degree of flowability. * The price on our website is for reference only. * Note: Data analysis service is not included in the list prices. Highlights: High Quality Data, Competitive Pricing, Technical Support by Scientists. Analytical Service Minimum order requirement: $250 per order. A $200 handling fee will be applied if order is below $250. Please contact [email protected] for additional information and instructions on our Analytical Services program. Confirmation of the sample(s) requirements, SDS sheets and additional information is needed prior to processing the Analytical Service order. ***Please do not ship any samples without authorization from MSE Supplies*** | Rheometer Analytical Service, Room temperature

MSE SuppliesSponsored
MSE PRO Profilometers for Optics Surface
MSE PRO™ Profilometers for Optics Surface MSE PRO™ Profilometers for Optics Surface is a versatile measurement solution designed for the optical lens industry. It can measure both surface roughness and profile in a single scan. The profilometer includes a dedicated software module for the measurement and analysis of large aspheric surfaces, making it ideal for optical lens applications. Additionally, this profilometer is suitable for measuring the profile and roughness of large, curved surfaces, such as bearings, artificial joints, precision molds, gears, and blades. This versatility makes it widely used in precision machining, automotive, bearings, machine tools, molds, precision hardware, and other industries. Product Features: Simultaneous profile and roughness parameter evaluation from a single scan. Superior precision, stability, and repeatability. Specialized aspheric optical software module. Advanced software analysis system with intelligent management. Built-in intelligent protection system for safe scanning. User-friendly manual control options. High-performance vibration isolation system for enhanced stability. MSE Supplies offers various optical metrology instruments. Please contact us for more information. Specifications: SKU# MA2229 Profile Measurement Measuring Range X 0~100 mm Z 0~300 mm Z1 ±6 mm (Optional: ±12 mm) Resolution 0.001 um Accuracy Z1 ≤ ± (0.5+0.03 H) μm (H, mm) Pt Pt ≤0.2 μm Standard Balt ≤ ± (1+R/20) μm (R, mm) Angle ≤ ±1' Moving Speed X 0~20 mm/s Z 0~20 mm/s Scanning Speed 0.05~5 mm/s X Straightness ≤0.15 μm/100 mm Measuring Force 0.5 mN, 0.75 mN, 1 mN, 2 mN, 3 mN (Adjustable) Roughness Measurement Ba Measurement Range Ra 0.012 μm ~ Ra 12.5 μm Accuracy Ra 0.012 μm~Ra 3.2 μm: ≤ ± (3 nm+2.0% A), A(Ra) μm Ra 3.201 μm~Ra 12.5 μm: ≤ ± (3 nm+3.5% A), A (Ra) μm Repeatability(1σ) 18 ≤ 1 nm Measurement Residual Rq ≤ 3 nm Filter Gaussian filter, 2RC filter, zero phase filter Sampling Length 0.008, 0.08, 0.25, 0.8, 2.5, 8.0 or 25 mm Selectable Evaluation Length Auto calculation Size (L×W×H) 600×350×890 (mm) Weight 195 kg | MSE PRO Profilometers for Optics Surface
See every ad you and competitors like MSE Supplies run in ChatGPT and Google AI Overviews, and the prompts that trigger them.
Data from Writesonic's ChatGPT and Google AI Overviews ad tracking, updated daily. How we collect it ↗ · Request a correction ↗